hitachivantara.vspone_block.vsp.hv_hur_facts module – Retrieves HUR information from Hitachi VSP storage systems.
Note
This module is part of the hitachivantara.vspone_block collection (version 3.4.0).
You might already have this collection installed if you are using the ansible
package.
It is not included in ansible-core
.
To check whether it is installed, run ansible-galaxy collection list
.
To install it, use: ansible-galaxy collection install hitachivantara.vspone_block
.
You need further requirements to be able to use this module,
see Requirements for details.
To use it in a playbook, specify: hitachivantara.vspone_block.vsp.hv_hur_facts
.
New in hitachivantara.vspone_block 3.1.0
Synopsis
This module retrieves information about HURs from Hitachi VSP storage systems.
For examples, go to URL https://github.com/hitachi-vantara/vspone-block-ansible/blob/main/playbooks/vsp_direct/hur_facts.yml
Requirements
The below requirements are needed on the host that executes this module.
python >= 3.8
Parameters
Parameter |
Comments |
---|---|
Information required to establish a connection to the storage system. |
|
IP address or hostname of the storage system. |
|
This field is used to pass the value of the lock token to operate on locked resources. |
|
Type of connection to the storage system. Choices:
|
|
Password for authentication. This is a required field. |
|
Username for authentication. This is a required field. |
|
Information required to establish a connection to the secondary storage system. |
|
IP address or hostname of the secondary storage system. |
|
Value of the lock token to operate on locked resources. |
|
Password for authentication for the secondary storage system. |
|
Username for authentication for the secondary storage system. |
|
Specification for the HUR facts to be gathered. |
|
The copy group name. If not provided, it will be omitted. |
|
The copy pair name. If not provided, it will be omitted. |
|
The local device group name. If not provided, it will be omitted. |
|
The mirror unit identifier. If not provided, it will be omitted. Choices:
|
|
The primary volume identifier. If not provided, it will be omitted. |
|
The remote device group name. If not provided, it will be omitted. |
|
The secondary storage serial number. If not provided, it will be omitted. |
|
The secondary volume identifier. If not provided, it will be omitted. |
|
Information about the storage system. This field is an optional field. |
|
The serial number of the storage system. |
Attributes
Attribute |
Support |
Description |
---|---|---|
Support: full |
Determines if the module should run in check mode. |
Examples
- name: Get all HUR pairs
hitachivantara.vspone_block.vsp.hv_truecopy_facts:
connection_info:
address: storage1.company.com
username: "admin"
password: "password"
secondary_connection_info:
address: storage2.company.com
username: "admin"
password: "secret"
- name: Gather HUR facts with primary volume and mirror unit ID
hitachivantara.vspone_block.vsp.hv_hur_facts:
connection_info:
address: storage1.company.com
username: "admin"
password: "password"
secondary_connection_info:
address: storage2.company.com
username: "admin"
password: "secret"
spec:
primary_volume_id: 111
mirror_unit_id: 10
- name: Gather HUR facts for a specific primary volume
hitachivantara.vspone_block.vsp.hv_hur_facts:
connection_info:
address: storage1.company.com
username: "admin"
password: "password"
secondary_connection_info:
address: storage2.company.com
username: "admin"
password: "secret"
spec:
primary_volume_id: 111
- name: Gather HUR facts for a specific secondary volume
hitachivantara.vspone_block.vsp.hv_hur_facts:
connection_info:
address: storage1.company.com
username: "admin"
password: "password"
secondary_connection_info:
address: storage2.company.com
username: "admin"
password: "secret"
spec:
secondary_volume_id: 111
Returned Facts
Facts returned by this module are added/updated in the hostvars
host facts and can be referenced by name just like any other host fact. They do not need to be registered in order to use them.
Key |
Description |
---|---|
A list of HURs gathered from the storage system. Returned: success |
|
ID of the consistency group. Returned: success Sample: |
|
Size of the copy pace track. Returned: success Sample: |
|
Rate of the copy process. Returned: success Sample: |
|
ID of the mirror unit. Returned: success Sample: |
|
Hexadecimal ID of the primary volume. Returned: success Sample: |
|
Name of the primary VSM resource group. Returned: success Sample: |
|
Hexadecimal ID of the primary virtual volume. Returned: success Sample: |
|
ID of the primary virtual storage. Returned: success Sample: |
|
ID of the primary virtual volume. Returned: success Sample: |
|
ID of the primary volume. Returned: success Sample: |
|
Storage ID of the primary volume. Returned: success Sample: |
|
Hexadecimal ID of the secondary volume. Returned: success Sample: |
|
Name of the secondary VSM resource group. Returned: success Sample: |
|
Hexadecimal ID of the secondary virtual volume. Returned: success Sample: |
|
ID of the secondary virtual storage. Returned: success Sample: |
|
ID of the secondary virtual volume. Returned: success Sample: |
|
ID of the secondary volume. Returned: success Sample: |
|
Storage ID of the secondary volume. Returned: success Sample: |
|
Status of the HUR. Returned: success Sample: |
|
Serial number of the storage system. Returned: success Sample: |
|
Access mode of the secondary volume. Returned: success Sample: |
|
Type of the HUR. Returned: success Sample: |